fix flow check and add reset when pump is off
This commit is contained in:
parent
8601e58d03
commit
37ef9a780d
2 changed files with 10 additions and 3 deletions
|
@ -9,7 +9,7 @@ uint16_t flow_counter=0; //maximum counts/s measured with Eden 128 Pump was 171
|
|||
|
||||
void flow_setup();
|
||||
void flow_loop(unsigned long loopmillis);
|
||||
bool checkFlow(float minflow,unsigned long maxtime);
|
||||
bool checkFlow(float minflow,unsigned long maxtime,bool reset=false);
|
||||
void IRAM_ATTR isr_flow();
|
||||
|
||||
unsigned long last_read_flow=0;
|
||||
|
@ -58,8 +58,12 @@ void flow_loop(unsigned long loopmillis) {
|
|||
|
||||
}
|
||||
|
||||
bool checkFlow(float minflow,unsigned long maxtime) { //L/min, milliseconds
|
||||
bool checkFlow(float minflow,unsigned long maxtime,bool reset) { //L/min, milliseconds
|
||||
static unsigned long last_flow_low=0; //0=flow ok
|
||||
if (reset) {
|
||||
last_flow_low=0;
|
||||
return true;
|
||||
}
|
||||
if (flow<minflow) { //flow too low
|
||||
if (last_flow_low==0) { //not set yet
|
||||
last_flow_low=millis();
|
||||
|
@ -74,6 +78,7 @@ bool checkFlow(float minflow,unsigned long maxtime) { //L/min, milliseconds
|
|||
}
|
||||
}
|
||||
|
||||
|
||||
void IRAM_ATTR isr_flow() {
|
||||
flow_counter++;
|
||||
flow_counter_sum++;
|
||||
|
|
|
@ -249,12 +249,14 @@ void loop() {
|
|||
pump_loop(loopmillis);
|
||||
#ifdef FLOW_PIN
|
||||
if (isPumpRunning(1)) { //Check pump 1 flow
|
||||
if (checkFlow(0.2, 20*1000)) {
|
||||
if (!checkFlow(0.2, 20*1000)) {
|
||||
Serial.println("pumpError flow too low");
|
||||
if (mqtt){
|
||||
publishInfo("error/pump","pumpError flow too low. flow="+String(flow));
|
||||
}
|
||||
}
|
||||
}else{
|
||||
checkFlow(0,0,true); //reset reset timer
|
||||
}
|
||||
#endif
|
||||
#endif
|
||||
|
|
Loading…