smartctl 7.0 2018-12-30 r4883 [x86_64-linux-5.3.0-26-generic] (local build)
|
|
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
|
|
|
=== START OF INFORMATION SECTION ===
|
|
Model Family: Western Digital RE4-GP
|
|
Device Model: WDC WD2002FYPS-01U1B1
|
|
Serial Number: WD-WCAVY4825044
|
|
LU WWN Device Id: 5 0014ee 204c1f986
|
|
Firmware Version: 04.05G05
|
|
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
|
Sector Size: 512 bytes logical/physical
|
|
Rotation Rate: 5400 rpm
|
|
Device is: In smartctl database [for details use: -P show]
|
|
ATA Version is: ATA8-ACS (minor revision not indicated)
|
|
SATA Version is: SATA 2.6, 3.0 Gb/s
|
|
Local Time is: Thu Jan 9 23:03:05 2020 CET
|
|
SMART support is: Available - device has SMART capability.
|
|
SMART support is: Enabled
|
|
|
|
=== START OF READ SMART DATA SECTION ===
|
|
SMART overall-health self-assessment test result: PASSED
|
|
|
|
General SMART Values:
|
|
Offline data collection status: (0x82) Offline data collection activity
|
|
was completed without error.
|
|
Auto Offline Data Collection: Enabled.
|
|
Self-test execution status: ( 0) The previous self-test routine completed
|
|
without error or no self-test has ever
|
|
been run.
|
|
Total time to complete Offline
|
|
data collection: (40260) seconds.
|
|
Offline data collection
|
|
capabilities: (0x7b) SMART execute Offline immediate.
|
|
Auto Offline data collection on/off support.
|
|
Suspend Offline collection upon new
|
|
command.
|
|
Offline surface scan supported.
|
|
Self-test supported.
|
|
Conveyance Self-test supported.
|
|
Selective Self-test supported.
|
|
SMART capabilities: (0x0003) Saves SMART data before entering
|
|
power-saving mode.
|
|
Supports SMART auto save timer.
|
|
Error logging capability: (0x01) Error logging supported.
|
|
General Purpose Logging supported.
|
|
Short self-test routine
|
|
recommended polling time: ( 2) minutes.
|
|
Extended self-test routine
|
|
recommended polling time: ( 459) minutes.
|
|
Conveyance self-test routine
|
|
recommended polling time: ( 5) minutes.
|
|
SCT capabilities: (0x303f) SCT Status supported.
|
|
SCT Error Recovery Control supported.
|
|
SCT Feature Control supported.
|
|
SCT Data Table supported.
|
|
|
|
SMART Attributes Data Structure revision number: 16
|
|
Vendor Specific SMART Attributes with Thresholds:
|
|
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
|
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 121
|
|
3 Spin_Up_Time 0x0027 150 149 021 Pre-fail Always - 9500
|
|
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 59
|
|
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
|
|
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
|
|
9 Power_On_Hours 0x0032 008 008 000 Old_age Always - 67488
|
|
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
|
|
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
|
|
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 59
|
|
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 50
|
|
193 Load_Cycle_Count 0x0032 088 088 000 Old_age Always - 336607
|
|
194 Temperature_Celsius 0x0022 126 082 000 Old_age Always - 26
|
|
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
|
|
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 45
|
|
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
|
|
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
|
|
200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
|
|
|
|
SMART Error Log Version: 1
|
|
ATA Error Count: 295 (device log contains only the most recent five errors)
|
|
CR = Command Register [HEX]
|
|
FR = Features Register [HEX]
|
|
SC = Sector Count Register [HEX]
|
|
SN = Sector Number Register [HEX]
|
|
CL = Cylinder Low Register [HEX]
|
|
CH = Cylinder High Register [HEX]
|
|
DH = Device/Head Register [HEX]
|
|
DC = Device Command Register [HEX]
|
|
ER = Error register [HEX]
|
|
ST = Status register [HEX]
|
|
Powered_Up_Time is measured from power on, and printed as
|
|
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
|
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
|
|
|
Error 295 occurred at disk power-on lifetime: 1943 hours (80 days + 23 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 80 83 3d 10 40 Error: UNC at LBA = 0x00103d83 = 1064323
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
40 00 80 80 3d 10 40 00 01:08:30.112 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:08:11.060 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:08:07.593 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:07:48.542 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:07:43.696 READ VERIFY SECTOR(S)
|
|
|
|
Error 294 occurred at disk power-on lifetime: 1943 hours (80 days + 23 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 80 83 3d 10 40 Error: UNC at LBA = 0x00103d83 = 1064323
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
40 00 80 80 3d 10 40 00 01:08:07.593 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:07:48.542 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:07:43.696 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:07:24.645 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:07:19.549 READ VERIFY SECTOR(S)
|
|
|
|
Error 293 occurred at disk power-on lifetime: 1943 hours (80 days + 23 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 80 85 3d 10 40 Error: UNC at LBA = 0x00103d85 = 1064325
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
40 00 80 80 3d 10 40 00 01:07:43.696 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:07:24.645 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:07:19.549 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:07:00.498 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:06:56.891 READ VERIFY SECTOR(S)
|
|
|
|
Error 292 occurred at disk power-on lifetime: 1943 hours (80 days + 23 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 80 85 3d 10 40 Error: UNC at LBA = 0x00103d85 = 1064325
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
40 00 80 80 3d 10 40 00 01:07:19.549 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:07:00.498 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:06:56.891 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:06:37.839 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:06:33.743 READ VERIFY SECTOR(S)
|
|
|
|
Error 291 occurred at disk power-on lifetime: 1943 hours (80 days + 23 hours)
|
|
When the command that caused the error occurred, the device was active or idle.
|
|
|
|
After command completion occurred, registers were:
|
|
ER ST SC SN CL CH DH
|
|
-- -- -- -- -- -- --
|
|
40 51 80 83 3d 10 40 Error: UNC at LBA = 0x00103d83 = 1064323
|
|
|
|
Commands leading to the command that caused the error were:
|
|
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
|
-- -- -- -- -- -- -- -- ---------------- --------------------
|
|
40 00 80 80 3d 10 40 00 01:06:56.891 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:06:37.839 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:06:33.743 READ VERIFY SECTOR(S)
|
|
ef 03 46 00 00 00 00 00 01:06:14.692 SET FEATURES [Set transfer mode]
|
|
40 00 80 80 3d 10 40 00 01:06:10.665 READ VERIFY SECTOR(S)
|
|
|
|
SMART Self-test log structure revision number 1
|
|
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
|
|
|
SMART Selective self-test log data structure revision number 1
|
|
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
|
1 0 0 Not_testing
|
|
2 0 0 Not_testing
|
|
3 0 0 Not_testing
|
|
4 0 0 Not_testing
|
|
5 0 0 Not_testing
|
|
Selective self-test flags (0x0):
|
|
After scanning selected spans, do NOT read-scan remainder of disk.
|
|
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
|
|